Correction Factors For Other Speeds
For speeds other than 1750, hydraulic performance and B.H.P. requirements must be corrected before a selection can be made. The following multipliers are used to correct performance and B.H.P.
| GPM. | Head | B.H.P. | |
| 1150 to 1750 | 1.52 | 2.31 | |
| 1750 to 1150 | .28 | ||
| 1450 to 1750 | 1.21 | 1.46 | |
| 1750 to 1450 | .58 | ||
| 2900 to 3450 | 1.19 | 1.42 | |
| 3450 to 2900 | .58 |
Sizing Procedure
|
Conversion Table |
|||||||
| Gallons | x | 3.785 | = Liters | Liters/Sec. | x | 15.85 | = GPM |
| GPM | x | .227 | = M3/HR | Liters | x | 0.264 | = Gallons |
| Ft. | x | .0348 | = Meters | M3/HR | x | 4.4 | = GPM |
| PSIG | x | .07 | = Kg/cm² | Meters | x | 3.281 | = Feet |
| HP | x | .7457 | = Kilowatt | Kg/cm² | x | 14.22 | = PSIG |
| IGPM | .83267 | = GPM | KW | x | 1.34 | = HP | |
| Bar | x | 14.50 | = PSI | Mpa | x | 146 | = PSI |
| CF/Sec. | x | 448.83 | = GPM | Kpa | x | 0.145 | = PSI |